INDUSTRIAL MEASUREMENT & PROCESS CONTROL
Technical resources
Flow measurementLiquid analysisLevel measurementPressure measurementTemperature measurementData & controlElemental analysis
Industrial instruments for liquid analysis
Liquid analysis

A clearer view of water quality

Connect analytical measurement to treatment and process control

Products/Liquid analysis/MPP1000
Liquid analysis
MODEL MPP1000

MPP1000 Online Water Quality Analyzer

A cabinet-based system combining several water-quality measurements.

Power supply
220 ±22 VAC, 50 ±1 Hz
Power consumption
30 W
Standard cabinet
800 × 506 × 180 mm; approximately 15 kg

Select the measurement range, process connection and output configuration for your application.

PRODUCT OVERVIEW

Understand the instrument

The MPP1000 brings selected analytical measurements into one online monitoring arrangement. Turbidity and disinfectant measurements can be combined with optional pH/ORP, conductivity and dissolved oxygen channels. Sample flow, inlet pressure and maintenance intervals need to be planned for the specific water conditions.

KEY FEATURES

Designed for the task

  • Multiple analytical channels in one system
  • RS485 Modbus-RTU interface
  • Optional analytical measurements
  • Optional heated operating configuration
TECHNICAL DATA

Specifications at a glance

Values below describe the listed product family. Optional ranges and functions depend on the selected configuration.

MPP1000 Online Water Quality Analyzer — technical specifications
ParameterSpecification
Power supply220 ±22 VAC, 50 ±1 Hz
Power consumption30 W
Standard cabinet800 × 506 × 180 mm; approximately 15 kg
Operating temperature4–50 °C; −25 to 50 °C with optional heating/antifreeze module
Working humidity≤95% RH, non-condensing
Sample inlet flow500–1,000 mL/min
Sample inlet pressure<3 kg/cm²
CommunicationRS485 Modbus-RTU plus wireless interface
Turbidity range options0–1, 0–20, 0–100 or 0–4,000 NTU
Residual chlorine / chlorine dioxide range0–5 or 0–20 mg/L
Optional pH/ORP range0–14 pH; ±2,000 mV ORP
Optional dissolved oxygen range0–20 mg/L
Expansion interfacesRS485, 4–20 mA

Confirm the final measuring range, material compatibility, operating limits and applicable approvals for the exact configuration before ordering. Product appearance may vary by version.

APPLICATION AREAS

Where it fits

  • Water treatment plants
  • Distribution and secondary water supply
  • Swimming pools and purified water
YOUR NEXT PROJECT STARTS HERE

Let’s specify your
next measurement

Talk to us about your process